- Home
- Products
Oil Gas Boiler
- WNS Series Liquid Fuel Oil Diese...
- Vertical Gas Lpg Diesel Hot Wate...
- SZS Series Double Drums Diesel G...
- Industrial Portable Skid-mounted...
- Waste Heat Recovery Steam Genera...
- Liquid Fuel Oil Diesel Heavy Oil...
- Liquid Fuel Oil Bunker Burner Bo...
- Gas Burner Boiler Natural Gas Lp...
- Industrial Biomethane Digester G...
Coal Boiler- Industrial Coal Fired Boiler Sol...
- Vertical Coal Boiler Small Solid...
- SZL Series Water Tube Boiler Dou...
- DZH Sereis Coal Charcoal Briquet...
- Small Hot Water Heater Boiler Ve...
- SHX/DHX Series Circulating Fluid...
- Briquette Coal Biomass Wood Hot ...
- Charcoal Wood Coal Hot Water Ste...
- Industrial Solid Fuel Water Heat...
Thermal Oil Boiler- Gas Lpg Diesel Fired Thermal Oil...
- Biomass Wood Thermal Oil Boiler ...
- Electric Thermal Oil Heater Boil...
- YQL Vertical Diesel Gas Fired Th...
- YLW Series Horizontal Coal Therm...
- Edible Oil Heater For Fryer
- Waste Heat Recovery Thermal Oil ...
- YGL Seires Vertical Wood Biomass...
- Small Gas Thermal Oil Heater
- About us
- Services
- Case
- News
- Contact us
Smokeless Waste Incinerator Medical Waste Household Waste Paper Plastic Waste Incinerator
- Incinerator For:Hospital medical waste, paper/plastic waste, household waste, domestic garbage, pet animal carcass, general waste
- Power:Gas, Diesel, Waste Oil, Lpg, Heavy Oil
- Disposal in :5-6 times one day around 10kg-5000kg
- Type:Semi-Automatic, Double Combustion Chambers
- Manufacture Standard:ISO CE
Smokeless Waste Incinerator Machine
Waste incinerator equipped with filter system, make it no pollution.
Filter device including: Rapid Cooling Tower, Venturi Dust Collector, Raschig Ring Filter Tower, Desulfurization/Denitration Tower, Cyclone Dust Separator, Activated Carbon Adsorption Tower, Bag Type Filter
Incinerator First Consumbustion Chamber Volume As Following:
YDF Series Pyrolysis Furnaces Incinerator for waste incineration are designed according to the CE directive and regulation, suitable for the incineration of clinical waste in healthcare facilities, clean and hassle-free disposal and safe destruction of:
1.Medical waste: syringes, neddles, gloves, straps, gauze, blood vessels, organs and other infectious waste.
2. Industrial waste (polymer waste): Plastic PE, PU, rubber (tire), Styrofoam, PET bottle, fiber, foam, cloth, bags, resin, acrylic, leather, Wood flour, urea powder, melon cloth, tapes, paints, polymers and so on.
3. General garbage: cardboard, paper scraps, sawdust, leaves and so on.
4. Special waste: waste oil, waste solvents, oil sludge, ash dust, iron paint, mold filter residue and so on.
5. Pet Animal carcass cremation.
Characteristics of Incinerator
1. Combustion chamber up to 1200ºC with a two tier system: mixed solid waste and char is incinerated in the superior tier
2. Grate ash collection to the lower tier: a drawer compartment for easy ash cleaning
3. After burner chamber: generated gases, fumes and smoke exhaust from the main chamber is processed and eliminated through high-temperature burn-out
4. Front-loading through side pantograph or hinged door
5. Configuration: Floor stand (castor wheels option)
6. Affordable, easy to operate and maintain
Global Sales Projects Site
Incinerator Spare Parts
Some Spare Parts With Incinerator
Models | YDF-20 | YDF-30 | YDF-50 | YDF-100 | YDF-150 | YDF-300 | YDF-500 | |
---|---|---|---|---|---|---|---|---|
Processing Capacity (kg/batch) | 10-20 | 20-30 | 30-50 | 50-100 | 100-150 | 200-300 | 300-500 | |
Working Hours Per Batch Cycle* (min) | 90-120 | |||||||
Primary Chamber Volume (m3) | 0.2 | 0.38 | 0.5 | 1 | 1.5 | 2.4 | 3.5 | |
Waste Feeding Gate Size (mm) | 380 x 480 | 480 x 600 | 620 x 800 | 700 x 900 | 760 x 960 | 900 x 1100 | 1080 x 1280 | |
Temperature (℃) | Primary Chamber | 900 | ||||||
Second Chamber | 1300 | |||||||
Smoke Residence Time (s) | > 2 sec in second chamber | |||||||
Applicable Waste Type | Hazard Medical Waste/Consumables, Plastic, Paper, Domestic Waste, Animal Corpse, Electronic Component | |||||||
Primary Burner - Baltur Italy | BTL-6, 0.11kw | BTL-6, 0.11kw | BTL-10, 0.11kw | BTL-10, 0.11kw | BTL-10, 0.11kw | BTL-10, 0.11kw | BTL-14, 0.18kw | |
Second Burner - Baltur Italy | BTL-10, 0.11kw | BTL-14, 0.18kw | BTL-14, 0.18kw | BTL-20, 0.18kw | BTL-20, 0.18kw | BTL-26, 0.25kw | BTL-35, 0.37kw | |
Total Diesel** Consumption (litre/h) | 11-18 | 11-18 | 14-23 | 16-35 | 16-35 | 20-40 | 38-57 | |
FD Fan Power (kw) | 0.37 | 0.37 | 0.55 | 0.75 | 0.75 | 0.75 | 0.75+0.75 | |
Applicable Voltage | 380V 3Phase / 220V 1Phase | |||||||
Outer Dimensions (m) | 1.6 x 1.3 x 2.65 | 1.45 x 0.9 x 2.6 | 1.8 x 1.2 x 3 | 1.86 x 1.4 x 3.2 | 2.1 x 1.5 x 3.5 | 2.25 x 1.6 x 3.8 | 3.0 x 2.0 x 4.8 | |
Chimney Dimensions (mm) | φ280 x 6000 | φ280 x 6000 | φ300 x 9000 | φ330 x 9000 | φ380 x 9000 | φ400 x 9000 | φ460 x 9000 | |
Weight (kg) | 2000 | 3000 | 5000 | 6800 | 8000 | 9600 | 15000 | |
Manufacturing Standard | GB 18484-2020 (equals to EPA or EU standards) |